Description
Product Specification
Input | |
AC Connection | 3L + N + PE |
Input Voltage (AC) | 3 Phase, 415 Vac +/- 10%, 50Hz |
Power Factor | >0.98 |
Current Nominal | 120 A per phase |
Efficiency | 94% |
Mains Terminal | Terminal blocks 3L + N + PE |
Transient | Class II/C protection |
DC Charging Points – CCS & CHAdeMO | |
DC Output Voltage | 200-500 Vdc |
Maximum Charge Power | 50 kW DC |
Cable Length | 5m |
Protections | Over Voltage protection,Under Voltage protection,Over Current circuit breaker,Short Circuit protection,Isolation Monitoring,Earth Monitoring |
DC Charging Point – CCS | |
Compliance | IEC 61851-23 / -24,IEC 62196-3,DIN 70121 |
Rating cable & gun | 125 Adc/600 Vdc |
DC Charging Point – CHAdeMO | |
Compliance | IEC 61851-23 / -24,JEVS G 105,Rev. 1.2 compliant |
AC Charging Point | |
Compliance | IEC-61851-22 |
AC socket 22 kW charge pt | IEC 62196-2 Mode 3, Type 2 |
Nominal AC voltage | 400 VRMS |
Maximum Charge Current/Power | 3 x 32 ARMS @ 22 kW point |
Protections | RCD Type B,Surge Protection,Over Current Breaker,Earth Monitoring |
User Interface & Control | |
Display | 7” Graphical Color display |
Language | English |
Push Button | Emergency Stop |
User Authentication | OTP Based/ RFID (Optional) |
Visual Indication | Mains Available, Charging Status, System Error |
Communication | |
Charger & Vehicle | PLC Communication(CCS) CAN Communication(CHAdeMO) Control Pilot (AC Type 2) |
Charger & CMS | Protocol: OCPP 1.6 (Open Charge Point Protocol) Interface : Ethernet, 2G/3G/4G |
General | |
Ingress Protection | IP55 |
Cooling | Air Cooled |
Ambient Temperature | – 25 to +45 °C |
Relative humidity | 95% max. non condensing |
Compliance | |
Communication Compliance | Tested over OCA compliant OCPP test tool |